DP-264-1C7Q

Hands-Free Video Door Phone

  • product_icon
  • product_icon
  • product_icon
  • Simple 2-wire connection
  • Remotely and securely talk to visitors and unlock doors, gates, etc. from the monitor
  • Easily connect 2 additional monitors and an additional camera
  • Camera has four IR LEDs for nighttime operation
  • Built-in microphone and speaker for hands-free two-way communication
  • Soft-touch button operation
  • Adjustable color tone, brightness, speaker, and ringer volume
  • 700 TV Lines resolution, large 7″ screen
Display Monitor: 7″ Color TFT
Operating voltage Monitor: 18VDC
Relock delay Monitor:5 seconds
Current draw Camera: 150mA Monitor: Active: 555mA, Standby: 20mA
E-lock delay Monitor: 1 second
IP Rating IP65 Weatherproof (Camera only)
Type Color camera
CMOS Camera: 1/3″ CMOS sensor
Resolution Camera: 700 TV lines
Lens Camera: 2.1mm
Relay output Camera: 3A@30VDC max. dry contact
Operating temperature Camera: -13°~149°F (-25°~65°C)
Weight Camera: 1-lb, 6-oz (750g) Monitor:1-lb, 2-oz (560g)
Dimensions Camera:4-7/16″x5-3/8″x2-1/16″ (112x136x52 mm) Monitor:9-1/2″x6-5/16″x1″ (241x161x25 mm) without sunshield

Product Information Sheet (PI)

MANUAL

The screen is black
  • Check that the camera is powered up.
  • Check that the power supply’s polarity is correct.
  • Check that the monitor is powered up.
  • Check that the video cable connecting the camera to the monitor is connected properly.
The screen image is dim
  • Clean the lens using a soft, clean cloth.
  • Check that the light source is adequate.
The screen image has poor color tone or flickers
  • Adjust the monitor’s color tone.
  • Adjust the monitor’s brightness.
  • Change the position of the camera.
  • Use untwisted wire and make sure the wiring distance does not exceed 230ft (70m)
The screen image is distorted.
  • Change the position of the camera.
  • Use untwisted wire and make sure the wiring distance does not
    exceed 230ft (70m)
  • Check End-of-Line resistor jumper is adjusted correctly on all monitor
The camera case is hot.
  • Check that the correct power supply is in use.
LEDs do not turn on.
  •  Check that the correct power supply is in use (18VDC).
  • Check that the wiring distance does not exceed 230ft (70m)
Lock button does not operate the relay
  • Check that the correct power supply is in use (18VDC).
  • Check that the wiring distance does not exceed 230ft (70m)

 

 