E-9622-4B25

IR Curtain Sensors for Indoor/Outdoor Access Control, 25ft

ENFORCER infrared photobeam curtain/barrier sensors are perfect for installation in windows, doorways, skylights, fence tops, any place where space is limited. Suitable for indoor and outdoor perimeter security, the trigger is programmable for simultaneous breaking of any single or 2 adjacent beams. The design features rugged aluminum construction, and an anti-tamper circuit for triggering an alarm if power is cut or the end cap is removed. No synchronizing wires are required and the LED alignment indicator makes installation easy. Mounting hardware is included.

  • product_icon
  • product_icon
  • Rugged aluminum construction
  • LED alignment indicator
  • No synchronizing wires required
  • NO/NC relay output
  • Weather-resistant IP54 construction
  • Slimline design (7/8″ x 1-5/16″ cross section)
  • Trigger by simultaneously breaking 2 adjacent beams or any single beam (programmable)
  • For windows, doorways, etc., where space is limited
  • Mounting hardware included
  • Multi-Frequency: Reduces interference and eliminates crosstalk when multiple units are used in close proximity to one another
Type IR Curtain Sensors for Indoor/Outdoor Access Control
Current Draw Standby – 89mA, Active – 73mA
Number of Beams 4
Sensing Range Up to 25′ (8m) outdoor, 50′ (16m) indoor
Operating Voltage 12~24VDC
Reaction time 0.5~32.5 ms
Detection System Simultaneous break of 2 adjacent beams or any single beam (programmable)
LEDs (On): powered, aligned properly, (Flash): when beam is broken, (Off): no power
Case material Weather-resistant IP54 / Aluminum alloy
Output NO/NC relay output, 1A @ 12~24VDC
Operating Temperature -49º~131º F (-45º~55º C)
Dimensions 22-1/2″ x 1-5/16″ x 7/8″ (572 x 33 x 22 mm) [Length x Width x Height]

Product Information Sheet (PI)

Manual

Transmitter LED will not turn ON
  • Test the power and ground wire with a voltage meter to ensure power is connected and is of the correct voltage.
  • Change the position of the transmitter jumper “JMP0”.
Receiver LED will not turn ON
  • Test the power and ground wire with a voltage meter to ensure power is connected and is of the correct voltage.
Receiver LED will not turn ON unless the sensor is triggered
  • Change the position of the receiver jumper”JMP1″.
Receiver LED flashes continuously
  • Check that the transmitter and receiver are aligned.
Does not trigger when beam is broken
  • Remount the curtain sensor away from any shiny surface, or repaint the surface to cut down on reflection.
Receiver continuously triggers the alarm
  • Check that the transmitter and receiver are aligned.
  • Check that the tamper button and the cover for the tamper button are mounted correctly.
False alarm
  • Re-install so that multiple sensors do not interfere with each other.
  • Cut back leafy vegetation.
  • Re-mount away from the edge of a roof.
  • Mount under a roof or shelter.