- Weatherproof (IP65) for indoor or outdoor perimeter security
- Long sensor range up to 190ft (60m) outdoors, 380ft (120m) indoors
- Install on windows, doorways, skylights, fence tops, and any place where space is limited
- End caps swivel so sensor can be mounted on a single wall or on opposite walls
- Programmable immediate trigger on simultaneous breaking of beams, or trigger after a single pair of beams is broken for at least 2 seconds
- Heater for use in cold weather operation
- Heater activates at 41ºF (5ºC)
- Terminal block wiring
- Slim design: 2-1/4″ x 1-7/8″ (55 x 49 mm)
- Rugged aluminum construction
- Built-in tamper switches, one on either end, trigger the alarm if end cap is removed
- No synchronizing wires required to align the beams
- Form C relay output
- LED and buzzer alignment indicators
- AGC (Auto Gain Control) circuits regulate beam signals in order to compensate for and ensure operation in rain, fog, and low-temperature conditions
- Programmable for 4 different frequencies to reduce interference between multiple units
Type | Long-Range Barrier Sensors for Indoor/Outdoor Access Control – Up to 380ft (120m) |
Number of Beams | 4 pairs |
Sensing Range | Outdoor- 190′ (60m), Indoor- 380′ (120m) |
Buzzer Active Current | 20mA@12VDC (RX) |
Heater Active Current | 160mA@12VDC (Rx+Tx) |
Rx Standby Current | (Buzzer off) 80mA, heater off (+/-25%@12VDC) |
Rx Trigger Current | (Buzzer on) 80mA, heater off (+/-25%@12VDC) |
Tx Standby & Active Current | 84mA, heater off, (+/-25%@12VDC) |
Input voltage | 12~24 VDC |
Operating Voltage | 12~24VDC |
Reaction time | 150/300/450/600 ms (DIP switch programmable) |
LEDs – Red | Alignment LED (Rx only), ON – beam is broken / OFF – aligned |
Detection System | Triggers as programmed when any 2 adjacent pair of beams are broken, or any single pair of beams is broken for over 2 sec. (programmable by JP2) |
Alarm Output | NO/NC/COM, relay output, active for 1 sec. when triggered |
Tamper Output | 1A@120VAC / 1A@24VDC (Tx & Rx) |
Case material | Aluminum housing / PC anti-UV cover / ABS end caps |
Operating Humidity | 0~95% |
Operating Temperature | -49º~131º F (-45º~55º C) |
Dimensions | 1-7/8″ x 2-1/4″ (49 x 55 mm) [Width x Height] |
Alignment Angle | Horizontal +/-90º |
Weight | 7.7-lb (3.5kg) [with brackets] |
Enclosure | Weatherproof IP65 |
Length | 43″ (109cm) |
Product Information Sheet (PI)
Manual
Receiver LED never turns ON and the buzzer never sounds | Test the power and ground wire with a voltage meter to ensure power is connected and is of the correct voltage |
Buzzer does not sound if the sensor is triggered | -If jumper J1 is plugged in, this indicates that the beams are not aligned -If jumper J1 is not plugged in, buzzer should never sound |
Receiver LED is ON and the buzzer sounds all the time | Realign the transmitter and receiver |
Does not trigger when beam is broken | -Remount the curtain sensor, or repaint the surface to cut down on reflection -Lower the response time (SW1) |
Receiver continuously triggers the alarm | -Realign the transmitter and receiver -Check that the tamper switch and the cover for the tamper switch are mounted correctly |
False alarm | -Reinstall so that one sensor does not interfere with another sensor -Cut back on leafy vegetation -Do not mount under the edge of the roof -Mount under a roof or shelter |