5 Separate zone inputs
- N.O. or N.C. (selectable) instant zone with exit delay.
- N.C. instant zone with exit delay.
- N.C. delay zone with entry and exit delays.
- N.O. 24-hour panic zone with no entry and exit delays.
- N.C. 24-hour tamper zone instant trigger no delay.
5 Zone shunting switches correspond to the 5 zone inputs. Shunt out any zone that is not working properly to prevent false alarms.
All inputs are super-high-transient protected.
3 Adjustable timers.
- Entry delay timer adjustable from 1 sec to 45 sec.
- Exit delay timer adjustable from 1 sec to 45 sec.
- Alarm duration timer adjustable from 3 sec to 20 min.
|
9 Status LEDs.
- (LEDs #1-5) Individual zone status green LEDs.
- Total zone status green LED. Indicates total zone status of the five zones.
- Arm/disarm/shunt status red LED. Indicates if alarm is armed, disarmed, or if a zone has been shunted.
- Entry/Exit status yellow LED. Indicates if alarm is in entry or exit delay mode.
- Primary power status red LED. Indicates if AC power is on or off.
- All 9 status LEDs visible when cabinet is closed.
|
2 Alert signals for entry and exit delay.
- Exit delay. A pulsed output during exit delay.
- Entry delay. A constant output during entry delay.
- Patented Automatic Extended Exit Delay (A.E.E.D.): Opening a switch/sensor connected to an exit delay zone before the exit delay elapses automatically extends the exit delay for as long as the switch/sensor remains open.
- Fail-safe circuitry: Alarm cannot be armed unless all switches and sensors connected to unshunted zones are in their non-violated state.
- Phase-II continual protection: To assure continuous protection, any input that remains triggered after the alarm duration has elapsed will shut down. All other inputs will remain armed.
- Multi-remote arm/disarm: Allows for the installation of up to 10 arming/disarming devices.
- Arm/disarm report output: Sends 100mA transistor ground signal to indicate alarm is armed or disarmed.
- Tamper output: Sends a 100mA transistor ground signal for as long as the tamper zone is activated.
- Dry relay contact panic output (C. - N.O.): Relay contacts close when the panic zone is activated.
- Positive voltage (3 Amp) relay alarm output: Powers signaling devices like a siren, bell, dialer, etc.
- Works on 16V AC/DC with back-up battery input:
- Use with DC adapter or Class-II transformer.
- Regulated power supply and recharger.
- Heavy-duty, beige-colored steel cabinet: Measures 8-1/2"x3-1/8"x11-7/16" (215x79x290 mm).
- Detachable front cover of steel cabinet.
- 2 tamper switches included: Detects if steel cabinet front cover opened or cabinet removed from wall.
|
|
|  |
|  |