Alarm Control Panel
E-295
Descriptions
5 Separate zone inputs
  • N.O. or N.C. (selectable) instant zone with exit delay.
  • N.C. instant zone with exit delay.
  • N.C. delay zone with entry and exit delays.
  • N.O. 24-hour panic zone with no entry and exit delays.
  • N.C. 24-hour tamper zone instant trigger no delay.
5 Zone shunting switches correspond to the 5 zone inputs. Shunt out any zone that is not working properly to prevent false alarms.
All inputs are super-high-transient protected.
3 Adjustable timers.

  • Entry delay timer adjustable from 1 sec to 45 sec.
  • Exit delay timer adjustable from 1 sec to 45 sec.
  • Alarm duration timer adjustable from 3 sec to 20 min.
9 Status LEDs.
  • (LEDs #1-5) Individual zone status green LEDs.
  • Total zone status green LED. Indicates total zone status of the five zones.
  • Arm/disarm/shunt status red LED. Indicates if alarm is armed, disarmed, or if a zone has been shunted.
  • Entry/Exit status yellow LED. Indicates if alarm is in entry or exit delay mode.
  • Primary power status red LED. Indicates if AC power is on or off.
  • All 9 status LEDs visible when cabinet is closed.
2 Alert signals for entry and exit delay.
  • Exit delay. A pulsed output during exit delay.
  • Entry delay. A constant output during entry delay.
  • Patented Automatic Extended Exit Delay (A.E.E.D.): Opening a switch/sensor connected to an exit delay zone before the exit delay elapses automatically extends the exit delay for as long as the switch/sensor remains open.
  • Fail-safe circuitry: Alarm cannot be armed unless all switches and sensors connected to unshunted zones are in their non-violated state.
  • Phase-II continual protection: To assure continuous protection, any input that remains triggered after the alarm duration has elapsed will shut down. All other inputs will remain armed.
  • Multi-remote arm/disarm: Allows for the installation of up to 10 arming/disarming devices.
  • Arm/disarm report output: Sends 100mA transistor ground signal to indicate alarm is armed or disarmed.
  • Tamper output: Sends a 100mA transistor ground signal for as long as the tamper zone is activated.
  • Dry relay contact panic output (C. - N.O.): Relay contacts close when the panic zone is activated.
  • Positive voltage (3 Amp) relay alarm output: Powers signaling devices like a siren, bell, dialer, etc.
  • Works on 16V AC/DC with back-up battery input:
  • Use with DC adapter or Class-II transformer.
  • Regulated power supply and recharger.
  • Heavy-duty, beige-colored steel cabinet: Measures 8-1/2"x3-1/8"x11-7/16" (215x79x290 mm).
  • Detachable front cover of steel cabinet.
  • 2 tamper switches included: Detects if steel cabinet front cover opened or cabinet removed from wall.
Small linked photo of E-295
View Enlargement

Installation Manual
Copyright 2006 by SECO-LARM U.S.A., Inc. All rights reserved. Modified:
Supplier of Security Systems and Accessories Worldwide.