ENFORCER® 295 Panel de Control de SECO-LARM®




5 Entradas, zonas separadas (super alta protección para transladarlo).
  • N.O. or N.C. (selectable) instant zone with exit delay.
  • N.C. instant zone with exit delay.
  • N.C. delay zone with entry and exit delays.
  • N.O. 24-hour panic zone with no entry and exit delays.
  • N.C. 24-hour tamper zone instant trigger no delay.

  • 5 Zonas y switches que se mantienen, correspondientes a las 5 salidas de las zonas. Shunt out any zone that is not working properly to prevent false alarmas.
    All inputs are super-high-transient protected.
    3 Ajustables temporizadores.

  • Entry delay timer adjustable from 1 sec to 45 sec.
  • Exit delay timer adjustable from 1 sec to 45 sec.
  • Alarm duration timer adjustable from 3 sec to 20 min.
  • Alarm Panel Picture
    Alarm Panel Box Open 9 LEDs estados, todos son visibles cuando el gabinete esta cerrado.
  • (LEDs #1-5) Individual zone status green LEDs.
  • Total zone status green LED. Indicates total zone status of the five zones.
  • Arm/disarm/shunt status red LED. Indicates if alarm is armed, disarmed, or if a zone has been shunted.
  • Entry/Exit status yellow LED. Indicates if alarm is in entry or exit delay mode.
  • Primary poder status red LED. Indicates if AC poder is on or off.
  • All 9 status LEDs visible when cabinet is closed.
    2 Señales de alerta para entrada y demora de salida..
  • Exit delay. A pulsed salida during exit delay.
  • Entry delay. A constant salida during entry delay.
  • Patented Automatic Extended Exit Delay (A.E.E.D.):  Opening a switch/sensor connected to an exit delay zone before the exit delay elapses automatically extends the exit delay for as long as the switch/sensor remains open.
    Fail-safe circuitry:  Alarm cannot be armed unless all switches and sensores connected to unshunted zones are in their non-violated state.
    Phase-II continual protection:  To assure continuous protection, any input that remains triggered after the alarm duration has elapsed will shut down. All other inputs will remain armed.
    Multi-remoto arma y desarma con la salida de reporte:  Allows for the installation of up to 10 arming/disarming devices.
    Arm/disarm report salida:  Sends 100mA transistor ground signal to indicate alarm is armed or disarmed.
    Tamper salida:  Sends a 100mA transistor ground signal for as long as the tamper zone is activated.
    Dry relay contact panic salida (C. - N.O.):  Relay contacts close when the panic zone is activated.
    Voltaje positivo (3 Amp) salida para el relevador de la alarma.:  Powers signaling devices like a siren, bell, dialer, etc.
    Works on 16V AC/DC with back-up batería input: 
    Use with DC adapter or Class-II transformer. 
    Fuente de poder regulado y recargador.
    Gabinete para uso pesado en color beige:  Measures 8 1/2" X 3 1/8" X 11 7/16" (215 x 79 x 290 mm).
    Detachable front cover of steel cabinet.
    2 Switches interruptores incluidos:  Detects if steel cabinet front cover opened or cabinet removed from wall.