Access Control Keypad     
SK-1011-SQ 100 Users, 1 relay output
Descriptions
  • 1 Output: Form C relay output (5A@28VDC).
  • 100 unique 4-8 digit codes, 111,110,000 possible user code combinations.
  • Stainless-steel face, durable and attractive.
  • Easily delete individual codes.
  • Programmable lockout after 5-10 unsuccessful attempts to key in code.
  • Output relay activation buzzer (programmable):
    Sounds while the output relay is activated.
  • Relay output inhibit control.
  • Auto or manual code entry checking:
    • Auto mode: All codes have the same number of digits, no # key required after each code.
    • Manual mode: Codes can vary in number of digits, # key must be pressed after every code.
  • Egress input: Lets users exit the protected premises without keying in the code.
  • Built-in tamper (N.C.) circuit.
  • EEPROM memory: Prevents data loss.
  • Power: 12~24V AC/DC.
Specifications


Type Digital Access Keypad
Number of user codes Up to 100
Operating voltage 12~24V AC/DC
Current drain  
       Standby 10mA@12VDC
       Key pressed Under 30mA@12VDC
       Relay active Under 80mA@12VDC
Relay output (1) 5A@28VDC, Form C, N.O./COM/N.C.
Tamper output N.C. dry contact
Egress N.O. ground
LED status Red - Inhibit /lockout mode, Green- relay activated, Amber - keypad status
Dimensions 4-5/8"x2-7/8"x1-7/8" (117x74x48 mm)
Weight 6.3-oz (180 grams)


Small linked photo of digital access-control keypad
View Enlargement

Product Info Sheet


Installation Manuals


Sample Ad


User Code Worksheet
Copyright 2008 by SECO-LARM U.S.A., Inc. All rights reserved. Modified:
Supplier of Security Systems and Accessories Worldwide.