SK-1123-SQ 110 Users, 2 relay outputs, surface mount
|
|
 |
- 2 relays:
5A@28VDC Form C, N.O./COM/N.C.
1A@28VDC Form C, N.O./COM/N.C.
- Each relay can be programmed for momentary (1-999 seconds) or latch.
- Code flexibility: Codes can be 4~8 digits long.
- Egress input for exiting the protected premises.
- Dual voltage: 12~24 VDC/VAC operation.
- Lifetime limited warranty.
- Tamper switch: N.C. dry contact 3A@12VDC.
- Mantrap - For a protected area with 2 doors, this feature allows only 1 door to be open at any time.
- All features are programmed directly from the keypad: No need for an external programmer.
- Duress output: signals a silent alarm if an authorized user is forced to open the door under duress.
- Keypad active output.
- Door-forced-open alarm output.
- Door-propped-open alarm output.
- Keypad can be programmed to emit beeps for key presses or operate in silent mode.
- EEPROM memory protects programmed information in case of power loss.
- Auto or manual code entry checking:
-- Auto: No # key required after each code.
-- Manual: # key must be pressed after every code.
- SK-1011-SQ and SK-1131-SQ Digital Access Keypads also available. Contact SECO-LARM for details.
- Low current draw suitable for solar applications.
|
|
|
 |
| Type |
Weather-Resistant Digital Access Keypad |
| Operating voltage |
12~24 VDC/VAC |
| Current draw |
|
| Standby |
15mA@12VDC |
| Key pressed |
45mA@12VDC |
| Relay active |
130mA@12VDC |
| Number of relays |
2 |
| Relay output (1) |
5A@28VDC, Form C, N.O./COM/N.C. |
| Relay output (2) |
1A@28VDC, Form C, N.O./COM/N.C. |
| Additional output |
Keypad active and alarm output |
| Egress |
N.O. ground, 3A@12VDC |
| Door sensor input |
N.C. |
| Dimensions |
4-15/16"x3-1/8"x2" (125x78x51 mm) |
| Weight |
18-oz (510 grams) |
|
|
 |
|  |