SK-2612-SPQ

Outdoor Stand-Alone / Wiegand Keypad with Proximity Reader

  • product_icon
  • product_icon
  • product_icon
  • 1,000 Users (up to 998 users and 2 duress users)
  • User code length 4~6 digits
  • 12~24 VAC/VDC Operation
  • Low current draw – 105mA max.
  • Form C relay output – 2A@12VDC
  • Adjustable output time – 0.5~99s, or toggle
  • Built-in tamper alarm and external alarm output
  • Backlit keypad and multicolor status LED
  • EM 125kHz
  • Outdoor rated – IP66
  • Easy transfer of users to additional devices
  • EEPROM Memory protects programmed information in case of power loss
  • All features are programmed directly on the keypad: No need for an external programmer
  • Egress input lets users exit the premises without keying in a code
  • Can serve as Wiegand reader or controller†, output and input – 26~37 bits
  • 2-Door interlock
  • Extreme cold tolerance to -40° F (-40° C)
  • Sturdy black ABS plastic housing

†Can serve as a Wiegand controller only when using another SK-2612-SPQ as a reader.

Operating Voltage 12~24 VAC/VDC
Current Draw Standby: 40mA@12VDC
Active: 105mA@12VDC (max.)
Outputs Form C: 2A@12VDC
Alarm: 2.5A@12VDC
Wiegand: 26~37 bits, PIN output bits – 4, 8, or 10
Egress input N.O. Ground
Door sensor input N.C. Ground
Weigand input 26~37 bits, PIN input bits – 4, 8, or 10
Card type EM 125kHz
Enclosure material Black ABS plastic
Operating temperature -40°~140° F (-40°~60° C)
Operating humidity 26~37 bits, PIN input bits – 4, 8, or 10
Card type EM 125kHz
Enclosure / IP Rating Black ABS plastic
Operating temperature -40°~140° F (-40°~60° C)
Operating humidity 10~90% non-condensing
Dimensions 1-15/16″x4-3/4″x15/16″ (49x120x24 mm)
Weight 5.8-oz (165g)

Product Information Sheet (PI)

Manual

Advertisement

Unit fails to accept a new user/duress code/card
  • Ensure the User ID assigned is between 0 and 997 for users and either 998 or 999 for duress codes/cards
  •  Ensure the user code is between 4~6 digits long and not already assigned to another user
Unit fails to respond to a programmed
user code/card
  • Ensure the unit is in standby mode by pressing the key until the LED becomes steady red