SB-P1012-26Q

Plug-and-Play 12VDC Realtime Backup Power for CCTV (Discontinued)

ENFORCER  Plug-and-Play Backup Power units provide backup power during temporary power outages, replaces the original 12VDC power adapter for a simplified installation.

  • product_icon
  • product_icon
  • Real-time backup power with no break when input power is lost
  • DC UPS Auto-start
  • Batteries provided by GE™ (2600mAh user-replaceable Lithium Ion – SB-P1012-26Q /2000mAh lithium polymer – SB-L10V1-20Q)
  • Over-discharge, overcharge, overload, short-circuit, and surge protection on input and output
  • LED indicators for power and backup operation
TypePlug-in UPS adapter
Input85~265VAC@50/60Hz
Input ProtectionOverload and short-circuit fuse
Output12VDC±5%
Output Power Rating10W
Output ProtectionOver-discharge, overload, short-circuit protection
BatteryReplaceable GE™ Li-Ion 18650 3.7VDC/2600mAh
Battery ProtectionOvercharge, over-discharge, overload, short-circuit, battery polarity
Backup TimeHalf Load – 70 min, Full Load- 30 min
LED IndicatorsPower, backup
Output Cord5.5ft / 1.4m
Output Plug5.5×2.1mm DC plug
Operating Temperature32~104°F (0~40°C)
Operating Humidity0~95% non-condensing
Dimensions3-7/16″ x 2-7/8 x “1-5/32” (87 x 59.8 x 29 mm)
Weight4.3-oz (122g)
Product Information Sheet (PI) (pdf, 0KB)
MANUAL (pdf, 0KB)
Backup time is shorter than
claimed
  • On initial installation, be sure that batteries have been charged for 24 hours before testing backup time
The power plug does not fit my unit
  • You may need to provide a power tip adapter to connect to your device (two adapters, both male and female)
Device does not turn on when
installed
  •  Check to see that all plugs are firmly connected at the device, the Backup Power unit, power adapter, and the AC wall outlet
  •  Check to see that the AC outlet is live
  •  Ensure that the Backup Power unit’s power LED is lit
  • Check for a short or overload. The Backup Power unit is designed to cut power when a short-circuit or overload is detected
  • Ensure that the battery’s polarity is correct and reverse if needed (SB-P1012-26Q)
  • Check that the device’s voltage is compatible (12VDC for the SB-P1012-26Q, and either 5, 7.5, 9, or 12VDC for the
    SB-L10V1-20Q)
  • If using the SB-L10V1-20Q, press the “Off/Reset” button to reset voltage output
During a power outage, power is not provided to device
  • Check for a short or overload. The Backup Power unit is designed to cut power when a short-circuit or overload is detected
  • Ensure that the Backup Power unit battery’s polarity is correct and reverse if needed (SB-P1012-26Q only
The alarm sounds (long beep) and the red alarm LED (SB-L10V1-20Q) is lit
  • Ensure that the input voltage is either 5, 7.5, 9, or 12VDC
  • Ensure that the original power adapter is working and providing power to the Backup Power unit
  • Ensure that the device’s current draw is no more than 10W
  • Check for a short-circuit at the device