SD-927PWCQ

Wave-to-Open Sensor – White plate

The ENFORCER Wave-to-Open Sensor uses IR technology to request egress from a protected area or activate a device with the simple wave of a hand. Since no touch is required, this sensor is suitable for use in hospitals, clinics, labs, cleanrooms (to reduce the risk of contamination), schools, factories, or offices.

  • product_icon
  • product_icon
  • Range up to 2″ (5cm)
  • White plastic single-gang plate
  • 3A relay, triggers minimum 0.5 sec or as long as hand is near the sensor
  • Quick connect screw-less terminal block
  • LED illuminated sensor area for easy identification
  • Selectable LED colors (turns from red to green or green to red) on sensor activation
  • Power must be provided by low-voltage power-limited/Class 2 power supply
  • Use only low-voltage field wiring and do not exceed 98.5ft (30m)
Operating voltage12VDC
Current draw (max.)50mA@12VDC
Relay typeForm C dry contact, 3A@30VDC
Response time10ms
LEDsStandby: Red*
Triggered: Green
Output time0.5 sec or as long as hand is near the sensor
Sensing range2″ (5cm)
Destructive attack levelLevel I
Line securityLevel I
Endurance levelLevel IV
Standby powerLevel I
Operating temperature-4°~131° F (-20°~55° C)
Weight2.5 oz (70g)

 

Product Information Sheet (PI) (pdf, 544KB)
Manual (pdf, 170KB)
Advertisement (pdf, 1491KB)

FAQs

Answer:

  1. Check that nothing is remaining in range of the sensor including a cone of 60º from the centerline.
  2. Reduce the IR range of the sensor.
  3. Ensure that the sensor’s output duration potentiometer is not turned to maximum
  4. Check that the power voltage is within the sensor’s specifications.

Answer:

  1. Ensure that no strong direct or reflected light source is reaching the sensor.
  2. Ensure that sensor is sheltered from direct sunlight.

Answer:

  1. Increase the IR range of the sensor.
  2. Check that the power voltage is within the sensor’s specifications.
Scroll to Top